Safe and efficient patient treatment is our common goal.

External radiation radiotherapy has revolutionized the way we treat patients with tumors-and the more accurate it is,the better the results.

Precise positioning is the cornerstone of patient safety, avoiding unprescribed doses and contributing to favorable outcomes through highly specific targeting of the tumor.
But how do you continuously hit the mark in long, complex treatments? How can this be integrated into a workflow that doesn't waste time or compromise patient safety and treatment efficiency?

crad02
 
crad04

CT Simulation is increasingly becoming the standard procedure in radiation therapy. But patient breathing, as well as movements of the tumor or normal tissue can impact planning, delivery and verification. With a normal CT scan, motion may cause inaccurate target definition, in that moving targets could be in distorted shapes at the wrong location. It could also cause extra dose distribution, in that moving targets could be in distorted shapes at the wrong location. It could also cause extra dose distribution to healthy tissue, due to dosing larger fields to cover a moving tumor.

To improve the visualization of moving tumors, 4D CT is applied to determine the motion and help to design an accurate plan for employing precise standard or gated therapy.

C-RAD Sentinel 4D CT is an easy-to-use, laser-based optical surface scanning system with functionality for 4D CT reconstruction and gated imaging in a CT room. It also provides reference images for patient positioning and intra-fraction motion detection in a radiation therapy treatment room.

crad02
 
crad07
 
crad06
 
Full 4D CT capability
  • Breath-hold, deep inspiration and coached/free breathing modes are all supported, along with retrospective and prospective modes. This provides maximum flexiblity to adapt to different patient capablilities and clinical requirements.
  • Patient baseline is calculated as an absolute parameter that can be used during the treatment delivery
  • The system offers seamless support throughout the entire 4D CT simulation, 4D treatment plaaning, and 4D delivery phases of the radiation therapy process.
High level of patient safety and user confidence
  • No markers or other equipment need to be placed on or around the patient.
  • Laser tracking system in the CT room for getting couch movement automatically
  • Tracking of both thoracic and abdominal respiratory motion in parallel with virtual monitoring.
  • Optional audio-visual coaching through in-room speakers and video goggles, assisting the patient to follow the optimal breathing pattern.
Sophisticated software to streamline the workflow
  • All data acuried by Sentinel is stored in a central database and the same surface points and breathing curve will be automatically tracked with a Catalyst™ system in the treatment room during every fraction, without manual intervention.
  • Multi-vendor interfaces have been developed to ensure a seamless clinical workflow, including GE, Philps, Siemens, Toshiba.

C-RAD is proud to present our innovative 4D SIGRT Solution based on the advanced Sentienl and Catalyst technologies.